Smoke DetectorA smoke detector is a safety device that detects airborne smoke and issues an audible alarm, thereby alerting nearby people to the danger of fire. Most smoke detectors work either by optical detection or by ionization, but some of them use both detection methods to increase sensitivity to smoke. History In 1902 George Andrew Darby, an electrical engineer of 211 Bloomsbury Street, Birmingham, England, patented the electrical Heat-Indicator and Fire Alarm. The device indicated any change of temperature in the apartment where it was fixed. The device operated by closing an electrical circuit to sound an alarm if the temperature raised above the safe limit. The contact was made by bridging a gap with a conductor, or allowing one plate to fall on another: this movement was caused simply by a block of butter which melted as the temperature raised. This early device subsequently gave way to more modern fire and eventually smoke alarms. Optical detector This type of detector includes a light source, a lens to collimate the light into a beam, and a photodiode or other photoelectric sensor at right-angles to the beam. In the absence of smoke, the light passes in front of the detector but does not fall on it. When visible smoke enters the beam, some light is scattered by the smoke particles, and some of the scattered light is detected by the sensor. An increased output from the sensor sets off the alarm. Ionization detector This type of detector is cheaper than the optical detector, and can detect particles of smoke that are too small to be visible. It includes a tiny mass of radioactive americium-241, which is a source of alpha radiation. The radiation passes through an ionization chamber, which is an air-filled space between two electrodes, and permits a small, constant current to flow between the electrodes. Any smoke that enters the chamber absorbs the alpha particles, which reduces the ionization and interrupts this flow of current, setting off the alarm. Batteries Most residential smoke detectors run on alkaline batteries. If these batteries run out, the smoke detector will become inactive. Most smoke detectors are designed to signal a low battery condition, but it is common for houses to have smoke detectors with dead batteries. As a result, public information campaigns have been created to remind people to change their smoke detector batteries regularly. In regions using daylight savings time, these campaigns usually suggest that people change their batteries when they change their clocks. Testing Most smoke detectors are equipped with a "test" button. Alternatively, artificial smoke can be purchased, which has the advantage of also testing the detector itself. Many people simply wave a lit match underneath the detector to test it. See also External links
|
 |
| |
|
|