Db(a)


   
dB(A) or dBA stands for decibels adjusted. It is the weighted absolute, calculated in dB (SPL) (decibels referenced to the sound pressure level SPL of 20 micropascal = 0 dBA).
   

Equal-loudness curves

The curves are based on the psophometric curves for human hearing; the equal-loudness contour. It is intended to approximate the level of human perception of noise. They are often used for determining the sound exposure of humans. The A indicates a certain frequency weighting representative for the noise sensitivity of the human ear. In Europe, the dBA is generally used in all sorts of noise regulations. dB(B) and dB(C) are similar measurements using different weighting curves. The curves approximate the human ear at different loudnesses, so only one of the curves should (theoretically) be chosen for a certain measurement, depending on the absolute signal level present. The curves are defined by the following transfer functions http://www.ptpart.co.uk/noise.htm:

A

{k_A \cdot s^4 \over (s+129.4)^2 (s+676.7) (s+4636) (s+76655)^2}

B

{k_B \cdot s^3 \over (s+129.4)^2 (s+995.9) (s+76655)^2}

C

{k_C \cdot s^2 \over (s+129.4)^2 (s+76655)^2}

D

{k_D \cdot s \cdot (s^2 + 6532 s + 4.0975 \times 10^7) \over (s+1776.3) (s+7288.5) (s^2 + 21514 s + 3.8836 \times 10^8)} The k values are constants which are usually used to normalize the function to a gain of 1 (0 dB) at 1 kHz. For A-weighting, kA = ~7.39705.
   
Note: The use of F1A-line or HA1-receiver weighting must be indicated in parentheses as required. A sound level of 0.63 pascal 1000 Hz tone will read +90 dBA, but the same sound pressure as white noise, randomly distributed over a 3 kHz band (nominally 300 to 3300 Hz), will read +82 dBA, due to the frequency weighting.
   
Manufacturers give the dBA rating for each appliance. The lower the rating the quieter the appliance when it is operating. The A-weighted noise floor of an audio system is often several dB lower than that measured with a flat-response device. In the field of audio electronics, it is therefore sometimes used in marketing literature to make systems seem better than they are.
   
Synonym: dBrn adjusted.
   
Source: from Federal Standard 1037C and from MIL-STD-188, plot of the filtercurve from J. Wolfe, University of New South Wales
   
     

 

<< PreviousWord BrowserNext >>
critical frequency
crosstalk
crypto
cryptochannel
crystal oscillator
curve fitting compaction
customer office terminal
customer premises equipment
customer service unit
custom local area signaling service
cutback technique
cutoff frequency
cutoff wavelength
subroutine
data access arrangement
data bank
data compaction
data element
data forwarder
data integrity
data link
data service unit
data signaling rate
data transmission circuit
date time group
db (car)
dbm
dbrn
data circuit terminating equipment
decollimation
decrypt
degradation
degree of isochronous distortion
degree of start stop distortion
dejitterizer
delay
delay encoding
delay line
delta modulation
demand assignment
demand factor
demand load
desensitation
design objective